NA-05 - Cleaning: Cleaning Nozzles

Jet angle

Jet angle (2)

The jet angle (also called exit angle) represents an essential parameter in high-pressure cleaning. It is the angle between the pressurized water jet and the pipe axis or longitudinal axis of the sewer, and may range between 0° and 90°.

Equation:
Pulling force

with:
FZ = Pulling force
FSt = Jet force
β = Jet angle
n = Number of jets (nozzle inserts)

Equation:
Cleaning force

with:
FR = cleaning force
FSt = Jet force
β = Jet angle

 

/ 109