Surge flushing
Surge flushing methods - performance comparison
Table:
Surge flushing methods - performance comparison
| Method | Flush length | Manufacturer | Literature |
|---|---|---|---|
| Flush gate, Slide gate, Flush sluice, Flush weir | > 1000 m (under favourable conditions, e.g. a straight flush lane) | Steinhardt GmbH Passavant GmbH ASA GmbH Liwatech PG | Guide to planning and application of surge flushing methods in combined sewers (Dohmann / Dettmar) |
| Tipping bucket | maximum 70 m | HST-Systemtechnik | |
| Vacuum operated flushing chamber | 160 m to 250 m | Biogest AG Steinhardt GmbH Liwatech PG | Guide to planning and application of surge flushing methods in combined sewers (Dohmann / Dettmar) |
| Pipe plug | approx. 350 m | HST-Systemtechnik GmbH | |
| Flush manhole | approx. 200 m | Funke GmbH |