BE-13 Renovation: Lining with Cured-In-Place Pipes - Processes - v01

UV Light Curing

Measurements

What is to be measured and recorded?

  • Electronic recording of the pulling speed of the UV light chain, the spot function (on/off)

  • Electronic measurement and recording of the temperature curves in the surface area of the liner while the UV light chain is being pulled through

  • Measurement of the radiation intensity while the UV light chain is being pulled through

  • Measurement of the installation pressure (internal pressure) and air temperature

For outside temperatures < 10 °C, special measures must be taken to heat the air in accordance with the specifications of the proof suitability certificate.

 