UV Light Curing
Measurements
What is to be measured and recorded?
-
Electronic recording of the pulling speed of the UV light chain, the spot function (on/off)
-
Electronic measurement and recording of the temperature curves in the surface area of the liner while the UV light chain is being pulled through
-
Measurement of the radiation intensity while the UV light chain is being pulled through
-
Measurement of the installation pressure (internal pressure) and air temperature
For outside temperatures < 10 °C, special measures must be taken to heat the air in accordance with the specifications of the proof suitability certificate.